UPS 6000VA/6000W, pF ≥ 0.99, Online technology, no batteries included
(additional battery pack required), LCD display, IEC connectors.
Rack/Tower convertible design, online double conversion with full digital control, wide input voltage range: 110~300Vac, input power pF 0.99 with PFC, selectable output voltage: 208/220/230/240Vac, Online double conversion design with input power factor correction (PFC) technology, achieving input power factor up to 0.99, digital control system for increased stability and reliability, ECO operation mode for improved energy efficiency and reduced user costs, three-stage charging: constant current charging, constant voltage charging and float charging stages are intelligently controlled, wide input voltage and frequency range for stable operation under various electrical scenarios and generators, comprehensive protections including output overload, output short circuit, overheating, low battery voltage warning, battery overcharge protection and self-diagnosis function power on, flexible LCD interface, SNMP card (not included).
Input voltage: 110~300V 40~70Hz (50/60Hz Auto-Sensing). Transfer time 0ms, charging time 4 hours (90%), operating temperature 0-40℃, convertible rack mount/free standing (rack mount rails are ordered separately),
dimensions 440 x 621.5x 86.5, weight 15.5kg. Warranty period: 24 months on electronics, 12 months on batteries
Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
Digital control system for enhanced stability and reliability.
ECO operation mode for improved energy efficiency and reduced user costs.
Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;
Power
UPS Capacity 6000 VA / 6000 W
Input
Nominal Voltage208/220/230/240Vac
PhaseSingle Phase
Input Voltage Range110~300Vac (110~300Vac@50% load/176~300Vac@100% load)
Input Frequency40~70Hz (50/60Hz Auto-Sensing)
Power factor≥0.99
Output
Output Voltage208/220/230/240Vac
Crest factor3:1
Power factor 1
Output Sockets
IEC version: Connecting terminal +IEC socket
US version: Connecting terminal+US socket panel
Output FrequencyOnline mode:±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) Battery mode: (50/60±0.1%)Hz
Harmonic distortion (THDv)
≤1% Linear load
≤3% Non linear load
Transfer TimeAC mode to Bat.mode: 0ms Inverter to Bypass: 0ms
Output WaveformPure Sinewave
Battery
Battery TypeValve Regulated Lead Acid (VRLA)
DC System Voltage (VDC)192/240Vdc (Settable)
Charging Current (Max.)12A
Expandable RuntimeYes, External battery pack: DS-UPSB09192A-R/TJ, or DS-UPSB09240A-R/TJ
Typical Backup TimeView Runtime Graph
Indicator
AlarmBattery mode/Battery low voltage/Overload/Fault
LCD displayInput voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Efficiency
AC ModeUp to 95%
Battery ModeUp to 93%
Environment
Operating Temperature0℃~40℃
Storage Temperature-25℃~55℃
Humidity Range0~95% (Non - condensing)
Altitude0~3000m (1000~3000m derating required)
Noise Level≤50dB
Physical
Dimension W x D x H (mm)440×621.5×86.5
Net weight (kg)15.5
Standards
SafetyCE-LVD IEC/EN 62040-1, IEC/EN 62477-1
EMCCE-EMC IEC/EN 62040-2 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, IEC61000-2-2)