UPS 3000VA/2700W, pF 0.9, Online technology, 6 pcs. included batteries 12V/9Ah, LCD display, terminals: IEC or Schuko. Rack/Tower convertible design, online double conversion with full digital control, wide input voltage range: 110~300Vac, input power pF 0.99 with PFC, selectable output voltage: 208/220/230/240Vac, Online double conversion design with input power factor correction (PFC) technology, achieving input power factor up to 0.99, digital control system for increased stability and reliability, ECO operation mode for improved energy efficiency and reduced user costs, three-stage charging: constant current charging, constant voltage charging and float charging stages are intelligently controlled, wide input voltage and frequency range for stable operation under various electrical scenarios and generators, comprehensive protections including output overload, output short circuit, overheating, low battery voltage warning, battery overcharge protection and self-diagnosis function power on, flexible LCD interface, SNMP card (not included).
Input voltage: 110~300V 40~70Hz (50/60Hz Auto-Sensing). Transfer time 0ms, charging time 4 hours (90%), operating temperature 0-40℃, convertible rack mount/freestanding (rack mount rails are ordered separately),
dimensions 440 x 600x 86.5, weight 26kg. Warranty period: 24 months on electronics, 12 months on batteries.
3000VA/2700W Uninterruptible Power Supply (With built-in battery)
Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
Digital control system for enhanced stability and reliability.
ECO operation mode for improved energy efficiency and reduced user costs.
Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;
Power
UPS Capacity 3000 VA / 2700 W
Input
Nominal Voltage208/220/230/240Vac
Input Voltage Range110~300Vac (176~264Vac @ 100% load)
Input Frequency40~70Hz (50/60Hz Auto-Sensing)
PhaseSingle Phase
Power factor≥0.99
Output
Output Voltage208/220/230/240Vac
Output WaveformPure Sinewave
Power factor 0.9
Output SocketsOptional: IEC panel/EU panel/UK panel/US panel
Output Frequency
Online mode: 46~54Hz or 56~64Hz
Bat. Mode: (50/60±0.1%)Hz
Crest factor3:1
Harmonic distortion (THDv)
≤3% Linear load
≤5% Non linear load
Transfer Time
AC mode to Bat.mode: 0ms
Inverter to Bypass: 4ms (Typical)
Battery
Battery TypeValve Regulated Lead Acid (VRLA)
Typical Recharging Time4 hours (To 90% of full capacity)
Capacity (Standard Unit)12V/9Ah
Battery Number6
DC System Voltage (VDC)72V
Charging Current (Max.)1A
Expandable RuntimeYes, External battery pack: DS-UPSB0972B-R/TJC
Typical Backup TimeView Runtime Graph
Indicator
LCD displayInput voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
AlarmBattery mode/Battery low voltage /Overload/Fault
Efficiency
AC Mode92%
Battery Mode88%
Environment
Operating Temperature0℃~40℃
Storage Temperature-25℃~55℃
Humidity Range20~95%RH @ 0~40℃ (Non condensing)
Altitude<1500m, derating required when>1500m
Noise Level<55dB at 1 Meter
Physical
Dimension W x D x H (mm)440 x 600 x 86.5
Net weight (kg)26
Standards
SafetyIEC/EN 62040-1, IEC/EN 62477-1
EMCIEC/EN 62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8