CDVI CT-V900-A Access control controller 2-Door
The CT-V900-A is at the heart of every Centaur access control system. The Centaur Server, hardware expansion modules, multi-purpose inputs, card readers, keypads and outputs are connected directly to the CT-V900-A. Multi-controller systems are networked via the RS-485 communication bus (or using the optional CA-ETHER-A over a TCP/IP network). Distributed database architecture allows each controller to make split-second decisions without needing to communicate with the Centaur server.
Lightning-quick, robust and remarkable stability make the CT-V900-A the professional’s choice.
-
Operates two doors on one side or one door on both sides
-
Possibility to control access to 6 additional doors (3x expansion modules CA-A470-A)
-
Memory for 10920 access control cards
-
256 access levels, 256 timetables
-
Buffer for 2048 events
-
16 observable inputs for MUK or REX
-
2 relay outputs for control of electric locks (12V dc / 24V dc)
-
Distributed database architecture
-
Possibility to update the firmware
-
Support for Wiegand, Track 2 ABA (magnetic stripe) and BCD (keyboard) access control readers
-
TCP / IP Ethernet interface via optional module
-
Intelligent expansion RS-485 communication bus allowing additional modules to be deployed up to 1200 m from the controller
-
E-Bus for connection to expansion modules for access control (max. 1220m.)
-
RS485 / RS-232 port for communication with CENTAUR software via serial port, dial-up or LAN / WAN (TCP / IP)
Technical Specifications:
Features:
Control 2 doors (Reader In / REX Out) or 1 Door (Reader In / Reader Out)
Add up to 6 more doors to the CT-V900-A using the CA-A470-A expansion module
10,920 on-board card database
256 Schedules
256 Access Levels
2048 Event Buffer
16 on-board inputs (*using ATZ 2R/3R)
2 on-board 12 Vdc or 24 Vdc field-selectable lock outputs
2 on-board Form C dry contact relay outputs (N/O – N/C)
Fully distributed database architecture (access decisions made locally)
Flash firmware – Upload firmware via the Centaur Server
E-Bus technology add-on hardware modules can be up to 1220m (4000ft) away from the CT-V900-A
2.5A switching power supply
Supports common Wiegand, Track 2 ABA (mag stripe) and BCD (keypad) formats
Easy maintenance with snap-off terminal blocks
Battery backup functionality (2 x 12V 7AH gel-type batteries)
Lithium battery protection in case of complete power failure
Communication:
RS-485 controller – expansion module network (9.6k or 19,2k baud)
Connect modules up to 1220m (4000ft) away from the controller
Plug and play technology
RS-232 support to communicate with the Centaur software via serial port, dial-up or LAN
Physical Specifications:
Cabinet size: 39cm (15.5”) high x 33cm (13”) wide x 10cm (4”) deep
PCB dimensions: 24.5cm (9.65”) x 20.2cm (7.95”)
Environment: 5°C to 55°C (41°F to 133°F)
Electrical Specifications:
Power input: 24Vac, 75VA or higher, 50/60Hz transformer
Supply current: 2.5A maximum
Battery capacity: Two 12Vdc, 7Ah, acid/lead gel cell batteries
Input Specifications:
Reader Inputs/Ports: 2
Keypad Inputs/Ports: 2
Multi-purpose Inputs: 16 (using ATZ 2R/3R)
Output Specifications:
12/24Vdc Lock outputs: 2
Relays: 2 Form C Dry Contact 5A/30VDC N.C/N.O.
Reader Outputs: Six 50mA Open collector outputs (Red/Green LEDs, Buzzer)
On-board Protection:
Auxiliary outputs: 2.5A (24VDC), 1A (12VDC & 5VDC) fuseless protection
AC protection: 5A fuse
Battery reversal: 7A fuse