The Bericacavi B67E02C080 is a shielded installation cable featuring two twisted pairs of solid 0.80 mm copper conductors. It includes PVC core insulation, aluminium/polyester tape shielding, a copper drain wire and a red PVC outer sheath. Designed for fixed wiring in fire detection, intrusion alarm and telephone systems, it helps reduce electromagnetic interference and supports reliable signal transmission. Supplied in a 100-metre roll
Full
The Bericacavi J-Y(St)Y BMK is designed for low-voltage signal transmission in fire alarm, intrusion detection and telephone installations. Its two twisted pairs provide four individual conductors for connecting compatible equipment.
The cable uses solid annealed copper conductors with PVC insulation. An aluminium/polyester (Al/PET) screen and a copper drain wire help minimise electromagnetic interference. The red PVC outer sheath provides protection and clear identification in fixed installations.
Suitable for indoor installation in dry or damp environments and temporary outdoor use, subject to installation requirements. It can be installed in conduits, pipes and cable trays, but is not intended for direct burial
Technical specifications
Specification
Details
Brand
Bericacavi
Series
J-Y(St)Y BMK
Product code
B67E02C080 — verify suffix
Manufacturer-listed code
B67E02C080TP
Number of pairs
2
Total conductors
4
Conductor diameter
0.80 mm
Conductor material
Solid annealed copper, Class 1
Core insulation
PVC
Core colours
Red/white and black/yellow
Pair assembly
PET tape
Shielding
Aluminium/polyester (Al/PET) tape
Drain wire
Annealed copper, 1×0.50 mm
Outer sheath
PVC
Sheath colour
Red, RAL 3000
Rated voltage
300/300 V
Maximum voltage
330 V
Test voltage
2,000 V
Maximum operating temperature
70°C
Short-circuit temperature
160°C
Minimum installation temperature
0°C
Average outer diameter
6.3 mm
Average weight
48 kg/km
Reaction-to-fire classification
Eca
Standard
EN 50575:2014 + A1:2016
Packaging
100 m roll